MCP 5100/5300/5500 Modular Circular Polarimeter

Polarimetry without limits

The new MCP 5100/5300/5500 continues the success story of the MCP 200/300/500. The new series combines state-of-the-art technology, modern design, and high usability. The LED light source technology for all wavelengths makes the MCP polarimeters virtually maintenance-free. The polarimeter allows customer-specific configurations and provides the widest range of options for the future, e.g.required wavelengths can be retrofitted on-site making the instrument ready for upcoming measuring tasks. MCP 5100/5300/5500 meets all application requirements for the determination of optically active substances and their concentration determination for the pharmaceutical, cosmetics, chemical, and medical industries, as well as for R&D.

Especificaciones técnicas

°OR at 589 nm
MCP 5100 MCP 5300 MCP 5500 MCP 5500 MW 325
Measuring scales °Optical Rotation, °Optical Rotation (cell-length corrected), °Specific Rotation, °Specific Rotation (cell-length corrected), % concentration (g/100 mL, g/L, g/100 cm³, kg/m³), °International Sugar scale (not temperature-compensated), mathematic functions and user-definable scales
Measuring range ± 89.9° ± 89.9° ± 89.9° ± 89.9°
Resolution 0.001° (0.0001° optional) 0.001° (0.0001° optional) 0.0001° 0.0001°
Accuracy* ± 0.0025° (± 0.0020° optional) ± 0.0020° < 0.0020° < 0.0020° (589 nm)
Repeatability ± 0.002° ± 0.002° ± 0.001° ± 0.001°
Response time 12 seconds 12 seconds 15 seconds 15 seconds
Wavelengths 589 nm and optionally up to eight wavelengths. Standard spectral wavelengths (365, 405, 436, 546, 578, 633, 880 nm), customer-specific wavelengths on request
Light source LED light source from 50 000 up to 100 000 hours lifetime for all wavelengths (325 nm to 880 nm)
Sensitivity Optical Density (OD) of 4.0 Optical Density (OD) of 4.0 at 589 nm
Temperature control and measurement
Sensor PT100 sensor for sample temperature measurement inside the cell or quartz control plate; wireless transfer to the instrument
Resolution 0.1 °C 0.01 °C 0.01 °C 0.01 °C
Accuracy** ± 0.1 °C ± 0.05 °C ± 0.03 °C ± 0.03 °C
Temperature control range*** 20 °C + 25 °C
(optional 10 °C to 45 °C)
10 °C to 45 °C
Dimensions, power requirements, interfaces
Dimensions (L x W x H) 797 mm x 437 mm x 231 mm
Weight 33.5 kg
Power management Power-supply self-adapting to any mains voltage, 100 to 240 VAC, 50/60 Hz
Power consumption 185 VA
Interfaces 4 USB, RS232, Ethernet, VGA, CAN bus. Easy connection of keyboard, mouse, printer, bar code reader and networks.
Accessories
Sample cells ToolMaster™: Wireless automatic identification of sample cells via RFID, sample cell path length from 2.5 mm to 200 mm
Quartz control plates Automatic identification of the quartz control plate and automated wireless transfer or reference parameters into the instrument

* under physical standard conditions

** with Peltier module and Toolmaster™ sample cell (50/100/200 mm)

*** the temperature control at 10 °C is under physical standard conditions

Normas

A

AOAC 940.11
AOAC 926.14
AOAC 954.14
AOAC 926.18
AOAC 970.57
AOAC 930.36
AOAC 920.82
AOAC 926.11
AOAC 898.02
AOAC 925.33
AOAC 902.02
AOAC 975.43
AOAC 950.30
AOAC 950.29
AOAC 945.37
AOAC 925.35
AOAC 930.32
AOAC 986.19
AOAC 920.65
AOAC 945.55
AOAC 933.04
AOAC 965.31
AOAC 925.52
AOAC 896.01
AOAC 925.47
AOAC 896.02
AOAC 920.190
AOAC 920.184
AOAC 920.189
AOAC 920.188
AOAC 920.182
AOAC 920.139

F

Farmacéutica europea 2.2.7 – Rotación óptica

U

USP 781 – Rotación óptica